10 kV用无源电子式电压传感器的应用研究
更新日期:2021-05-25     浏览次数:144
核心提示:摘要针对传统技术中采用电磁式CT互感器存在的不足,提出了适用于10 kV的无源电子式电压互感器。根据电压互感器的工作原理,介绍了10 kV无源电子式电压互

摘要 针对传统技术中采用电磁式CT互感器存在的不足,提出了适用于10 kV的无源电子式电压互感器。根据电压互感器的工作原理,介绍了10 kV无源电子式电压互感器在电能表检定装置方面的意义。进一步分析了无源电子式电压互感器在电力设备中应用的重要性和必要性,该技术能够有效地避免传统技术在电力线路信号传输和处理时带来附加误差,大大提高电能计量、保护和测量系统的精度,推进了电力系统朝向数字化、电子化、自动化、网络化的方向发展。实验表明,采用10 kV的无源电子式电压传感器与传统CT互感器相比,误差精度提高了10%以上。 Aiming at the shortcomings of the traditional technology using electromagnetic CT transformers,a passive electronic voltage transformer suitable for 10kV is proposed.According to the working principle of the voltage transformer,a 10 kV passive electronic voltage transformer is proposed in the energy meter.The significance of the verification device further analyzes the importance and necessity of the application of passive electronic voltage transformers in power equipment.This technology can effectively avoid the additional errors caused by traditional technology in power line signal transmission and processing,which greatly improves The accuracy of electrical energy measurement,protection and measurement systems has promoted the development of power systems towards digitalization,electronics,automation,and networking.Tests show that compared with traditional CT transformers,the error accuracy of passive electronic voltage sensors using 10 kV is improved by more than 10%.
作者 丁永生 李自清 DING Yong-sheng;LI Zi-qing(State Grid Electric Power Research Institute Co.,Ltd.,Nanjing,Jiangsu 211000,China;Shanghai Zhixin Electric Co.,Ltd.,Shanghai 200335,China)
出处 《计算技术与自动化》 2021年第1期53-57,共5页 Computing Technology and Automation
基金 江苏省科技厅资助项目(5230JY18000X)。
关键词 CT互感器 无源电子式电压互感器 光电式电压互感器 全光纤型传感器 误差精度 CT transformer passive electronic voltage transformer photoelectric voltage transformer all-fiber sensor error accuracy